BZQDF - UNDERCOATS, 4515 BODY UNDERCOATING AND DEADENER

  • MSDS: BZQDF
  • Manufacturer: MARTIN SENOUR CO
  • Product Name: UNDERCOATS, 4515 BODY UNDERCOATING AND DEADENER
  • National Stock Number: 8010-00N064613
Product Identification

Product ID:UNDERCOATS, 4515 BODY UNDERCOATING AND DEADENER
MSDS Date:09/01/1992
FSC:8010
NIIN:00N064613
MSDS Number: BZQDF

Responsible Party
MARTIN-SENOUR CO
101 PROSPECT AVE NW
CLEVELAND, OH 44115
US

Emergency Phone: 216-566-2917

Info Phone: 216-566-2902

Cage: 16772

Contractor
MARTIN-SENOUR CO THE DIV SHERWIN-WILLIAMS CO
CHICAGO, IL 60608-5724 US

Cage: 16772

Ingredients

KEROSENE (PETROLEUM), HYDROTREATED; (MINERAL SPIRITS) VP

CAS: 64742-47-8

RTECS: OA5504000

Fraction By Weight: 35%

OSHA PEL 100 PPM (MFR)

ACGIH TLV: 100 PPM (MFR)


ASPHALT; (ASPHALT (PETROLEUM))

CAS: 8052-42-4

RTECS: CI9900000

Fraction By Weight: 45%

OSHA PEL N/K

ACGIH TLV: 5 MG/M3 (FUME)


ALUMINOSILICATE

CAS: 1327-36-2

Fraction By Weight: 5%

OSHA PEL N/K

ACGIH TLV: N/K


1); (CALCIUM CARBONATE)

CAS: 471-34-1

RTECS: FF9335000

Fraction By Weight: 10%

OSHA PEL N/K

ACGIH TLV: N/K


2.9 LBS/GAL - TOTAL AND LESS

RTECS: 9999999VO

OSHA PEL N/K

ACGIH TLV: N/K


& HEATERS. TURN OFF STOVES, ELEC TOOLS &

RTECS: 9999999ZZ


NFPA CODE. USE APPRVD BONDING & GROUNDING PROCS.

RTECS: 9999999ZZ


APPRVD CNTNRS W/COMPLETE & APPROP LABELING. DO NOT

RTECS: 9999999ZZ


DUSTS ARE LISTED, APPLIC LIMS FOR NUISANCE

RTECS: 9999999ZZ


(TDUST), 5 MG/M3 (RESPIRABLE FRACTION).

RTECS: 9999999ZZ


GENERATED FROM THIS PRODUCT, UNDERLYING PAINT OR

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:IRRIT OF EYES, SKIN & RESP SYS.
MAY CAUSE NERVOUS SYS DEPRESS. EXTREME OVEREXP MAY RSLT IN UNCON &
POSS DEATH. HDCH, DIZZ, NAUS & LOSS OF COORDINATION INDICATE EXCESS
EXPOS TO VAPS/SPRAY MISTS. REDNESS & ITCH/BURN SENSATION MAY
INDICATE EYE/EXCESS SKIN EXPOS. CHRONIC:SOME ANIMAL STUDIES W/POOR
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:CTLS INDICATED BITUMENS(ASPHALT) CAUSE
TUMORS, HOWEVER, THERE IS INADEQ EVID BITUMENS ALONE ARE CARCIN TO
HUMANS. PRLNGD OVEREXP TO LISTED SOLV INGREDS MAY CAUSE ADVERSE
EFTS TO LIVER, URINAR Y, BLOOD FORMING, CVS & REPRO SYS. RPTSHAVE
ASSOC RPTD & PRLNG OVEREXP TO SOLVS W/PERM BRAIN & NERVOUS SYS
DMG.(SUPDAT)
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.

First Aid

First Aid:INHAL: REMOVE FROM EXPOSURE. RESTORE BREATHING. KEEP WARM AND
QUIET. SKIN: WASH AFFECTED AREA THOROUGHLY WITH SOAP AND WATER.
REMOVE CONTAMINATED CLOTHING AND LUANDER BEFORE REUSE. EYES: FLUSH
EYES WI TH LARGE AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. GET
MEDICAL ATTENTION. INGEST: SEEK MEDICAL ATTENTION.

Fire Fighting

Flash Point:115F,46C
Lower Limits:1.0%
Upper Limits:7.0%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP.
WATER SPRAY MAY BE INEFTIVE. IF WATER IS USED, FOG NOZZS ARE PREF.
WATER MAY BE USED TO COOL CLSD CNTNRS(SUPDAT)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPKS & OPEN FLAME. CLSD CNTNRS MAY EXPLODE WHEN
EXPOS TO EXTREME HEAT. APPLICATN TO HOT SURFS (SUPDAT)

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPKS & OPEN
FLAME. DURING USE & UNTIL ALL VAPS ARE GONE: KEEP AREA VENT. DO NOT
SMOKE. EXTING ALL FLAMES, PILOT LIGHTS (ING 6)
Other Precautions:USE ONLY W/ADEQ VENT. AVOID BRTHG VAP & SPRAY MIST.
AVOID CNTCT W/SKIN & EYES. COATING MAY CNTN MATLS CLASSIFIED AS
NUISANCE PARTICULATES WHICH MAY BE PRESENT AT HAZ LEVELS ONLY
DURING SANDING/ABRADIN G OF DRIED FILM. IF NO SPECIFIC (ING 9)

Exposure Controls

Respiratory Protection:IF PERSONAL EXPOS CANNOT BE CONTROLLED BELOW
APPLIM LIMS BY VENT, WEAR NIOSH/MSHA APPRVD, PROPERLY FITTED ORG
VAP/PARTICULATE RESP. WHEN SANDING/ABRADING DRIED FILM, WEAR
DUST/MIST RESP APPRVD BY NIOS H/MSHA FOR DUSTS WHICH MAY BE (ING
11)
Ventilation:LOC EXHST PREF. GEN EXHST ACCEPTABLE IF EXPOS IS MAINTAINED
BELOW APPLIC EXPOS LIMS. REFER TO OSHA STDS 1910.94,107,108.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:WASH HANDS AFTER USING.
Supplemental Safety and Health
FIRE FIGHT PROC:TO PVNT PRESS BUILD-UP & POSS AUTOIGNIT/EXPLOS WHEN
EXPOS TO EXTREME HEAT. EXPLO HAZ:REQS SPEC PRECS. DURING EMER
CNDTNS OVEREXP TO DECOMP PRODS MAY CAUSE HLTH HAZ. SYMPS MAY NOT BE
IM MED APPARENT. OBTAIN MED ATTN. EFTS OF OVEREXP: INTENTIONAL
MISUSE BY DELIB CONC & INHAL CONTENTS MAY BE HARMFUL/FATAL.

Chemical Properties

Boiling Pt:B.P. Text:>142F,>61C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:0.90-0.99
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:>70

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BY FIRE: CARBON DIOXIDE, CARBON
MONOXIDE.

Disposal

Waste Disposal Methods:WASTE FROM PROD MAY BE HAZ AS DEFINED UNDER RCRA
40 CFR 261. WASTE MUST BE TESTED FOR IGNITABILITY TO DETERM APPLIC
EPA HAZ WASTE NUMBERS. INCIN IN APPRVD FACILITY. DO NOT INCIN CLSD
CNTNRS. DISPOSE O F I/A/W FED, STATE & LOC REGS REGARDINGPOLLUTION.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.